跳到正文

生理信号处理与研究分析

使用 NeuroKit2 处理心电、光电容积脉搏和其他生理信号,组织信号清洗、特征提取与研究分析。

开源精选医疗业务23 个文件50,135 Stars浏览次数 0K-Dense-AI/scientific-agent-skills MIT版本 a1043ef
开始使用

适用环境:Python 3.10+ and uv; pinned workflows use NeuroKit2 0.2.13. Core processing needs NumPy, SciPy, pandas<3, scikit-learn, matplotlib, PyWavelets, requests, and setuptools; selected EEG, cvxEDA, plotting, file-format, and RQA features need separately locked optional packages.

输入资料
获准使用的生理信号与采样信息 研究目标和 NeuroKit2 环境 阅读本节完整说明
交付内容
信号处理与特征资料 研究分析和质量检查记录 阅读本节完整说明
环境与依赖
For optional features, create a uv project, add only the packages actually required at reviewed exact versions, and commit/review the resulting uv.lock before uv sync --locked. NeuroKit2 exposes an upstream full extra, b… 阅读本节完整说明
  1. 获取完整包,保留配套文件的目录结构。
  2. 按照原文准备所需工具、依赖与输入资料。
  3. 阅读对应使用步骤与输入输出说明,在自己的环境中验证结果。

使用提示摘自原文,配套文件保留来源版本;实际运行条件以各包说明为准。

正文

获取原文件

references/signal_processing.md

Checked 2026-10-01 against NeuroKit2 0.2.13, its stable wheel, tagged source, and the live signal API page (0.2.13.dev214).

Start with a signal contract

For every channel retain:

  • sensor/channel identity and physical unit;
  • native sampling rate and timestamps;
  • polarity, gain, acquisition filters, and ADC range;
  • missing/discontinuous intervals and artifact annotations;
  • expected physiological bandwidth; and
  • the exact NeuroKit2 function, method, parameters, and package version.

signal_sanitize() does not clean artifacts or interpolate missing values. In 0.2.13 it resets an indexed pandas Series to a default index.

Safe preprocessing order

  1. Preserve the original samples and time axis.
  2. Check timestamp order, rate, clipping, flatlines, non-finite values, and gaps.
  3. Split at long gaps. Interpolate only short, prespecified gaps and retain a mask.
  4. Remove offsets/trends only when justified.
  5. Apply a modality/method-specific filter at the native rate.
  6. Trim or flag filter transients.
  7. Detect/correct peaks or derive features.
  8. Resample continuous outputs only when alignment or modeling requires it.

Do not use a filter to “fix” clipping, sensor detachment, dropped packets, or motion. Do not interpolate event markers, quality flags, or peak indicator vectors as continuous amplitudes.

Verified 0.2.13 interfaces

Function Stable behavior relevant to schemas
signal_filter() Returns one array. Default is order-2 Butterworth; available behavior depends on method, cutoffs, and sampling rate.
signal_sanitize() Resets pandas Series indexing; it is not a NaN/artifact cleaner.
signal_fillmissing() Forward, backward, or both-direction fill only (method="forward", "backward", or "both").
signal_resample() Returns one array; accepts target length or source/target rates. Methods include interpolation, FFT, polyphase, NumPy, and pandas paths.
signal_interpolate() Returns interpolated values; explicitly provide source and target coordinates for irregular time.
signal_findpeaks() Returns a dict. The pinned default synthetic probe observed Peaks, Height, Distance, Onsets, Offsets, and Width; keys can change with input/method.
signal_fixpeaks() Returns (info, corrected_peaks) in stable source. Default Kubios info includes artifact categories and diagnostics.
signal_period() Takes peak locations and returns period in seconds, optionally interpolated to a requested sample length.
signal_rate() Takes peak locations and returns events/minute, optionally interpolated.
signal_psd() Returns a DataFrame; the pinned Welch probe observed Frequency and Power.
signal_power() Returns a one-row DataFrame with band-derived names such as Hz_0.5_2; names depend on requested bands.
signal_timefrequency() Returns (frequency, time, representation); frequency is the first object.
signal_synchrony() Returns an array; supported methods are Hilbert phase synchrony and rolling correlation.
signal_decompose() Returns a component array; stable methods are EMD and SSA, not a component dictionary.
signal_changepoints() Implements PELT and returns change-point sample indices.

Never unpack signal_psd() into (psd, frequencies) in 0.2.13:

psd = nk.signal_psd(
    signal,
    sampling_rate=250,
    method="welch",
    normalize=False,
    show=False,
)
frequency_hz = psd["Frequency"]
power = psd["Power"]

normalize=True scales by maximum PSD power. It is not physical calibration. Use normalize=False when absolute spectral units are required and derive those units from the acquisition and estimator.

Filtering and resampling

Cutoffs are in Hz and must lie below Nyquist. Report:

  • filter family and implementation (butterworth, FIR, Savitzky–Golay, powerline);
  • order, low/high cutoff, notch frequency, and whether processing is zero phase;
  • padding/edge handling and samples discarded; and
  • source and target sampling rates plus resampling method.

Example:

filtered = nk.signal_filter(
    signal,
    sampling_rate=250,
    lowcut=0.5,
    highcut=40,
    method="butterworth",
    order=2,
)
resampled = nk.signal_resample(
    filtered,
    sampling_rate=250,
    desired_sampling_rate=100,
    method="poly",
)

Downsampling requires anti-alias filtering. In 0.2.13 the default interpolation method uses spline interpolation (scipy.ndimage.zoom), not an anti-alias low-pass filter. Use a suitable explicit filter before decimation or a validated filtered resampler such as poly; check attenuation above the new Nyquist frequency. Resampling cannot recover timing precision or bandwidth absent from the acquisition. For multimodal data, preserve native processing and timestamps first; choose a common grid only after clock alignment.

Missing data

Forward/backward fill can create artificial constant segments. Generic interpolation can create smooth but fictional morphology and peaks. Record:

  • count and maximum run of missing samples;
  • gap durations in seconds;
  • whether each gap was segmented, excluded, padded, or interpolated;
  • interpolation method and maximum allowed gap; and
  • whether downstream quality and uncertainty include the imputed mask.

Most modality pipelines may warn and internally forward-fill some missing samples. That convenience is not a study-level missing-data policy.

Peak correction

info, corrected = nk.signal_fixpeaks(
    peaks,
    sampling_rate=250,
    method="Kubios",
    iterative=True,
)

The Kubios/Lipponen–Tarvainen path is intended for ECG/PPG beats. method="neurokit" supports explicit interval limits and can be used more generically. Always retain raw and corrected peaks, counts by artifact category, affected time ranges, and results with and without correction. Do not call corrected beat intervals “normal-to-normal” unless the study actually identifies non-sinus/ectopic beats.

Quality and reproducibility

Useful QC is multimodal and method-specific:

  • raw/clean overlays and filter-edge review;
  • missing, flatline, clipping, and saturation fractions;
  • peak/onset overlays and interval distributions;
  • quality values with their method-specific direction and scale;
  • sensitivity to plausible filter/detector settings; and
  • synthetic fixtures plus labeled empirical validation data.

The bundled inspector is dependency-free:

python skills/neurokit2/scripts/inspect_signal.py \
  --input signal.csv --root . --deidentified \
  --columns ECG --time-column time_s --units ECG=mV

Sources checked 2026-10-01