正文
获取原文件assets/nca-reporting-checklist.md
Record the applicable conventions and provenance below. The bundled helper uses one global BLQ rule, so location-dependent handling requires documented preprocessing.
The four conventions that change the answer
- Trapezoidal rule: linear / linear-up-log-down / log-linear
- BLQ handling, stated separately for each position:
- leading (before the first quantifiable sample): [ zero / excluded ]
- embedded: [ zero / LLOQ÷2 / excluded ]
- trailing: [ excluded / other ]
- Lambda_z selection: the rule, the minimum number of points, whether Tmax was excluded, and the window and point count actually used for each subject
- AUCinf basis: observed Clast or predicted Clast
Data
- Analyte, matrix, assay, LLOQ, and the bioanalytical validation report reference
- Actual elapsed times used, not nominal — and nominal times used only for grouping
- Dose actually administered per subject, including any deviations
- Records excluded, with the reason, and confirmation the criteria were set before unblinding
- Deviations in sampling time above [ ]% of the nominal time, and how they were handled
Parameters reported
- Cmax and Tmax as observed values, never interpolated
- AUClast, AUCinf (both observed- and predicted-based, or one with the basis stated)
- % AUC extrapolated, per subject
- lambda_z, t½, and the number of points and time span of the terminal fit, per subject
- CL or CL/F, Vz or Vz/F — with
/Fused for every extravascular route - Vss only for intravenous data
- At steady state: AUC(0-tau), Cavg, Cmin, PTF%, accumulation ratio — and not AUCinf
- Partial AUCs, if pre-specified, with their intervals
Terminal-phase quality, per subject
- Adjusted r-squared of the lambda_z regression
- Span ratio (window duration ÷ t½); below 2 is a screening flag, not a universal exclusion
- % AUC extrapolated; above 20% is a screening flag, not a universal exclusion
- Number of points in the fit; flag below 3
- Subjects for whom lambda_z was not estimable, and how they were handled in the summary
Summary statistics
- Exposure metrics (AUC, Cmax) as geometric mean and geometric CV%
- Tmax as median and range
- Arithmetic mean, SD and CV% where relevant to the estimand, with the summary basis stated
- n for each parameter, since it differs when lambda_z fails for some subjects
Presentation
- Individual concentration-time profiles on both linear and semi-logarithmic axes
- Mean profiles with a stated rule for handling BLQ in the mean
- A table of individual parameters, not only summary statistics
Method and provenance
- Software and version
- Units for every parameter, and confirmation that dose and concentration units are consistent
- Whether the analysis was pre-specified, and the reference to the plan
- Any deviation from the plan, with its reason
The traps this checklist exists to catch
- Reporting AUCinf from a truncated steady-state profile.
- Interpolating Cmax, or reporting a mean Tmax.
- Quoting Vz as if it were Vss, or reporting Vss from oral data.
- Applying one BLQ rule to the test arm and another to the reference.
- Using a summary basis that does not match the estimand or comparing incompatible summaries.
- Summarising across subjects without saying that lambda_z failed for some of them.
- Omitting the lambda_z window, which makes the half-life unreproducible.